  instruction sheet terminating head 58062- 1 for ampmodu* mass termination (mt) 408--9085 loc b 1 of 5 e 2010 tyco electronics corporation, harrisburg, pa all international rights reserved te logo and tyco electronics are trademarks. *trademark. other products, logos, and company names used are the property of their respective owners. tooling assistance center 1--800--722-- 1111 product information 1--800--522--6752 this controlled document is subject to change. for latest revision and regional customer service, visit our website at www.tycoelectronics.com 04 feb 10 rev b receptacle connectors figure 1 channel ramp feed channel slot wire inserter adjuster (inserter rod) anti--backup pawl (not shown) feed slide (not shown) wire guide note: adapter for single--row connectors not shown 1. introduction terminating head 58062--1 is designed to terminate unstripped discrete wire sizes 30 through 20 awg onto ampmodu mt receptacle connectors having a single row (reference part number 1--102747--7) or double row (reference part number 102393--1) of contacts with spacing on 2.54 2.54 mm [100 100 in.] centerlines. the head must be used with one of the following power units (for operating procedure, refer to the instructions packaged with the power unit). power unit instruction sheet (408) or customer manual (409) pistol grip manual handle assembly 58074--1 408--6790 pistol grip pneumatic handle assembly 58075--1 408--6789 pneumatic power bench assembly 58338--1 408--9393 electric power unit 931800--1 409--5746 dimensions in this instruction sheet are in millimeters [with inches in brackets]. figures are not drawn to scale. reasons for reissue of this instruction sheet are provided in section 8, revision summary. 2. description (figure 1) features of the head and their function are as follows: wire inserter?forces the wire into the slotted beams of the contact. wire guide?holds the connector properly in relation to the wire. adjuster (inserter rod)?is a piston for, and regulates the travel of, the wire inserter. feed slide?automatically advances the connector after each termination. anti--backup pawl?prevents the connector from moving out of position after it has been advanced by the feed slide. an adapter is included with the head that must be used for terminating single--row connectors. after the head is installed onto the power unit, it serves as a guide and support for the connector during termination. the arrow on the top of the head indicates the direction that the connector will move in the head. the wires are terminated onto the connector using the insulation displacement technique. 3. setup 1. for single--row connectors, refer to figures 1 and 2, and install the adapter onto the head as follows: a. align the side of the adapter with the side of the head so that the bottom starts at the slot and the clip starts at the ramp. b. slide the adapter into the slot until the clip drops into the channel. 2. install the head onto the power unit according to the instructions packaged with the power unit. make sure to observe any cautions and dangers. note i
408- 9085 terminating head 58062- 1 rev b 2 of 5 tyco electronics corporation figure 2 clip ramp adapter slide adapter into slot installing adapter (used for single- row connectors only) 4. termination procedure make sure that the connector matches the wire size to be terminated, then refer to figure 3, and proceed as follows: 1. align the side of the connector with the side of the head (so that it will move in the direction of the arrow), and slowly slide the connector into the feed channel. stop when the desired contact position aligns with the wire slot. if the connector cannot be inserted into the head or if the connector is too loose in the head, refer to paragraph 5.2 for wire guide adjustment. 2. insert the wire into the wire slot until the wire bottoms on the head. figure 3 wire wire slot slide connector into feed channel power unit (ref) connector (double row shown) terminating connector 3. center the wire in the wire slot, then actuate the power unit until the wire inserter bottoms (the wire inserter will retract and the connector will advance to the next contact position). 4. center the wire in the wire slot, then actuate the power unit until the wire inserter bottoms (the wire inserter will retract and the connector will advance to the next contact position). 5. repeat steps 1 through 3 until all applicable contacts are terminated. 6. slide the connector out of the head in the direction of the arrow. 7. inspect each terminated contact according to figure 4. if any contact does not meet the requirements, do not use the connector. refer to section 5 for adjustments. for application requirements for the connectors, refer to the appropriate application specification: 114--25019 for single--row connectors and 114--25032 for double--row connectors. 5. adjustments for pneumatic power units, to avoid personal injury, always disconnect the air supply before making adjustments to the head. for electric power units, to prevent personal injury, always disconnect the electrical power supply before making adjustments to the head. 5.1. wire insertion depth if the wire is inserted too deep or not deep enough in the contact after termination, adjust the wire insertion depth as follows: a. pneumatic power units increase the air pressure by 10 psi [69 kpa]. repeat the termination and inspection procedure. continue in this manner until the proper wire insertion depth is obtained or the air pressure is set to 70 psi [483 kpa]. if proper wire insertion depth is not obtained at 70 psi [483 kpa], return the air pressure to 40 psi [276 kpa] and follow paragraph b. for pneumatic power units, it might be necessary to adjust either the wire insertion depth or the air pressure. note i note i danger danger note i
408- 9085 terminating head 58062- 1 3 of 5 rev b tyco electronics corporation figure 4 top of wire conductor below topofwirebarrelslot top of w i re barrel slot correct acceptable t e r m i n a t i o n i n s pect i o n incorrect wire was not inserted deep enough during termination wire was not inserted straight before termination wire was not fully inserted before termination wire was inserted with too much force during termination damaged housing? connector was too tight or too loose in head during termination a a 0.51 [.020] min section a--a arms of insulation support barrel partially closed arms of insulation support barrel completely closed ampmodu mt receptacle connector b. manual and electric power units 1. remove the head from the power unit according to the instructions packaged with the power unit. make sure to observe any cautions and dangers. 2. turn the adjuster one--sixth of a revolution clockwise if the wire is too deep in the contact, and counterclockwise if the wire is not deep enough in the contact. refer to figure 5. this will decrease or increase the wire insertion depth by approximately 0.20 [.008]. 3. install the head onto the power unit according to the instructions packaged with the power unit. make sure to observe any cautions and dangers. figure 5 turn clockwise to decrease wire insertion depth turn counterclockwise to increase wire insertion depth adjuster wire insertion depth adjustment
408- 9085 terminating head 58062- 1 rev b 4 of 5 tyco electronics corporation 5.2. wire guide if the connector cannot be inserted into the head, the connector is too loose in the head, or the connector housing is damaged after termination, refer to figure 1, and adjust the wire guide as follows: 1. for pneumatic power units, disconnect the air supply. for electric power units, disconnect the electrical power supply. 2. loosen the two screws on the wire guide. 3. slide the wire guide until the connector fits properly in the head. 4. finger--tighten the screws. 6. inspection and maintenance 6.1. inspection regular inspections should be performed by quality control personnel with a record of quality control inspections remaining with the personnel responsible for the head. one inspection per month is the recommended frequency; however, operator training and skill, amount of use, working conditions, and established company standards are all factors to be considered in establishing inspection frequency. 6.2. daily maintenance 1. remove dust, moisture, and other contaminants with a clean, soft brush or lint--free cloth. do not use objects that could damage the head. 2. make sure that all components are in place and properly secured. 3. make sure that the mechanisms inside the head function smoothly. 6.3. periodic maintenance 1. remove any accumulated film with a suitable cleaning agent that will not affect plastic. 2. check for chipped, cracked, worn, or broken areas on the head. if damage is evident, repair or replace the head. 7. replacement and repair customer--replaceable parts are listed in figure 6. a complete inventory should be stocked and controlled to prevent lost time when replacement of parts is necessary. parts other than those listed should be replaced by tyco electronics to ensure quality and reliability. order replacement parts through your representative, or call 1--800--526--5142, or send a facsimile of your purchase order to 717--986--7605, or write to: customer service (038--035) tyco electronics corporation po box 3608 harrisburg pa 17105--3608 for customer repair service, call 1--800--526--5136. 8. revision summary revisions to this instruction sheet include s updated document to corporate requirements
408- 9085 terminating head 58062- 1 5 of 5 rev b tyco electronics corporation 1 14 2 3 4 6 7 9 5 13 12 10 11 8 a a section a--a 84.07 [3.31] 25.4 [1.0] 44.45 [1.75] replacement parts item part number description qty per head 1 312331--1 head 1 2 28593--1 screw, self--tapping 2 3 312332--1 housing, insert 1 4 312333--1 pawl 2 5 1--23147--2 spring, compression 2 6 312334--1 inserter, wire 1 7 312335--1 guide, wire 1 8 4--23715--7 screw, machine, 4--40 .750 in. l 2 9 3--21028--2 pin, slotted spring 1 10 312149--1 adjuster 1 11 22488--5 spring, compression 1 12 312148--2 rod, inserter 1 13 312336--1 slide, feed 1 14 312337--1 adapter, single--row 1 figure 6


▲Up To Search▲   

 
Price & Availability of 312148--2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X